Home > Products > Gamma Sterilizable Capsule Filter > KleanCap Gamma Irradiation Sterilizable Nylon Membrane Capsule Filters
                                      KleanCap Gamma Irradiation Sterilizable Nylon Membrane Capsule Filters
                                      • KleanCap Gamma Irradiation Sterilizable Nylon Membrane Capsule FiltersKleanCap Gamma Irradiation Sterilizable Nylon Membrane Capsule Filters

                                      KleanCap Gamma Irradiation Sterilizable Nylon Membrane Capsule Filters

                                      Get a quote for KleanCap Gamma Irradiation Sterilizable Nylon Membrane Capsule Filters from MS factory when you need naturally hydrophilic Nylon in an all-polypropylene capsule with no IPA pre-wetting required. Superior flow per unit area and gamma sterilization compatibility make it practical for aqueous, beverage and fine chemical applications.

                                      Send Inquiry

                                      Product Description

                                      Order KleanCap Gamma Irradiation Sterilizable Nylon Membrane Capsule Filters from MS when high flow and operational simplicity are priorities. The naturally hydrophilic Nylon membrane does not require IPA pre-wetting or DI water flushing, eliminating a contamination source. The all-polypropylene construction provides excellent chemical compatibility, and these capsules deliver superior flow per unit area.


                                      Application Guidance: Where Nylon Capsules Excel

                                      Solvents: compatible with mild organic solvents in an all-PP construction.

                                      Parts cleaning: aqueous solutions filtered without pre-wetting steps.

                                      Fine chemicals: high flow supports clarification throughput.

                                      Ink jets: particulate reduction protects print nozzles.

                                      Process water: clarification and bioburden reduction in utility streams.


                                      Filter Area and Strength

                                      Filter Area: 7000 cm² / 10"

                                      Minimum burst pressure: 123.5 psi (8.5 barg)


                                      Materials of Construction

                                      Filter Media: Nylon

                                      End Caps: Polypropylene

                                      Inner Core: Polypropylene

                                      Outer Cage: Polypropylene


                                      Compliance

                                      USP Class VI 121°C plastics

                                      FDA 21 CFR and EU 10/2011 basis


                                      Integrity Test Specifications

                                      Pore Size

                                      Bubble Point

                                      0.1‌μm

                                      3.5 barg@20°C

                                      0.2‌μm

                                      2.8 barg@20°C

                                      0.45‌μm

                                      1.8 barg@20°C

                                      0.65‌μm

                                      1.1 barg@20°C


                                      Typical Flow Rate in water, 10"


                                      Ordering Information

                                      For KleanCap Gamma Irradiation Sterilizable Nylon Membrane Capsule Filters, specify pore size, connection type, and capsule length. MS can help confirm membrane compatibility with your process fluid.

                                      Pore size

                                      Housing

                                      Length

                                      Fittings

                                      Vent

                                      Drain

                                      001=0.1μm

                                      002=0.2μm

                                      004=0.45μm

                                      006=0.65μm

                                      0022=0.2/0.2μm

                                      0064=0.65/0.45μm

                                      I=In-line

                                      T=T-line

                                      03=2.5"

                                      05=5"

                                      10=10"

                                      20=20"

                                      30=30"

                                      40=40"

                                      1HT=1.5"TC

                                      MT=1/2"TC

                                      08H=1/2" Hose Barb

                                      12H=3/4" Hose Barb

                                      1/2"NPT-M

                                      8NF=1/2"NPT-F

                                      S=Staubli

                                      H=Hose Barb

                                      S=Staubli

                                      H=Hose Barb



                                      Hot Tags: KleanCap Gamma Irradiation Sterilizable Nylon Membrane Capsule Filters, China, Manufacturer, Supplier, Factory, Durable, Advanced, Customized, Standardized Dimensions