Home > Products > Gamma Sterilizable Capsule Filter > KleanCap Gamma Irradiation Sterilizable Nylon Membrane Capsule Filters
KleanCap Gamma Irradiation Sterilizable Nylon Membrane Capsule Filters
  • KleanCap Gamma Irradiation Sterilizable Nylon Membrane Capsule FiltersKleanCap Gamma Irradiation Sterilizable Nylon Membrane Capsule Filters

KleanCap Gamma Irradiation Sterilizable Nylon Membrane Capsule Filters

───────────────────────────────────────3) KleanCap Gamma Irradiation Sterilizable Nylon Membrane Capsule FiltersSummaryGet a quote for KleanCap Gamma Irradiation Sterilizable Nylon Membrane Capsule Filters from MS factory when you need naturally hydrophilic Nylon in an all-polypropylene capsule with......

Send Inquiry

Product Description

───────────────────────────────────────

3) KleanCap Gamma Irradiation Sterilizable Nylon Membrane Capsule Filters

Summary

Get a quote for KleanCap Gamma Irradiation Sterilizable Nylon Membrane Capsule Filters from MS factory when you need naturally hydrophilic Nylon in an all-polypropylene capsule with no IPA pre-wetting required. Superior flow per unit area and gamma sterilization compatibility make it practical for aqueous, beverage and fine chemical applications.


Introduction

Order KleanCap Gamma Irradiation Sterilizable Nylon Membrane Capsule Filters from MS when high flow and operational simplicity are priorities. The naturally hydrophilic Nylon membrane does not require IPA pre-wetting or DI water flushing, eliminating a contamination source. The all-polypropylene construction provides excellent chemical compatibility, and these capsules deliver superior flow per unit area.


Application Guidance: Where Nylon Capsules Excel

Solvents: compatible with mild organic solvents in an all-PP construction.

Parts cleaning: aqueous solutions filtered without pre-wetting steps.

Fine chemicals: high flow supports clarification throughput.

Ink jets: particulate reduction protects print nozzles.

Process water: clarification and bioburden reduction in utility streams.


Filter Area and Strength

Filter Area: 7000 cm² / 10"

Minimum burst pressure: 123.5 psi (8.5 barg)


Materials of Construction

Filter Media: Nylon

End Caps: Polypropylene

Inner Core: Polypropylene

Outer Cage: Polypropylene


Compliance

USP Class VI 121°C plastics

FDA 21 CFR and EU 10/2011 basis


Integrity Test Specifications

Pore Size

Bubble Point

0.1‌μm

3.5 barg@20°C

0.2‌μm

2.8 barg@20°C

0.45‌μm

1.8 barg@20°C

0.65‌μm

1.1 barg@20°C


Typical Flow Rate in water, 10"


Ordering Information

For KleanCap Gamma Irradiation Sterilizable Nylon Membrane Capsule Filters, specify pore size, connection type, and capsule length. MS can help confirm membrane compatibility with your process fluid.