Sterilisation grade polyethersulfone cartridges are 100% integrity tested and made from a single hydrophilic, asymmetric PES membrane. It offers broad chemical compatibility, high filtration area, high flow rates at low pressure drop, and low extractables. Filtration areas as low as 500 cm^2 can be achieved with pore sizes of 0.1 µm, 0.2 µm, 0.45 µm, 0.65 µm, 0.8 µm, and 1.2 µm. Minimum bubble points of 70 psig (4.8 bar) are possible. If you want to know more about General Filtration PES Mini Filter Cartridge, please contact us.
·Bottled Water
·Process Water
·Vinegar
·Aseptic Packaged liquids
·Beer, Wine and Spirits
·Juice,Soft Drinks,Edible Oils
·Optical Disk manufacturing
·Hard Disk manufacturing
·Optical Coatings
·Bulk Chemicals
·Pharmaceutical intermediates
H:500cm^2 S:1000cm^2
D: 1500cm^2 L:2100cm^2
Water wetted membrane
Pore size | Minimum Bubble point |
0.1um | 70 psig(4.8 bar) |
0.2um | 45 psig(3.1bar) |
0.45um | 24 psig(1.7 bar) |
0.65um | 19 psig(1.3 bar) |
0.8um | 17 psig(1.2 bar) |
1.2um | 11.6psig(0.8 bar) |
Differential Pressure
·Forward 50 psid (3.4 bard) at 20 ℃(68°F)
·Reverse 40 psid (2.7 bard) at 20 ℃(68 'F)
Operating Temperature 82 ℃C(180 'F) at 10 psid(0.69 barg)in water
Recommended ChangeoutPressure:35psid(2.4barg)
Filtered Hot Water 90 ℃(194°F), 30 minutes, multiple
cycles,max 3 psid forward flow
Autoclave 121℃(250'F),30 min,multiple cycles
In-line Steam 135℃(275'F),30 min,multiple cycles
All components meet the specifications for biological safety per USP Class VI-121'C for plastics.
Filter Membrane:Polyethersulfone(PES)Membrane
Media Support: Polypropylene
End Caps:Polypropylene
Inner Core:Polypropylene
Outer Cage: Polypropylene
Sealing Method:Thermal Bonding
O-rings: Buna, Viton(or FKM), EP, Silicone,
Encapsulated Silicone,
Encapsulated Viton (or FKM)
Materials of construction comply with FDA regulations for food and beverage contact use as detailed in the US Code of Federal Regulations, 21CFR.Materials used to produce filter media and hardware are safe for use in contact with foodstuffs in accordance with EU Directives
PORE SIZE |
AREA |
ENDCAPS |
SEAL |
CONNECTION SUPPORT |
|
|
|
|
|