Buy General Application Capsule filters Nylon membrane from MS when your process requires a hydrophilic nylon 66 capsule that balances throughput, cleanliness, and documented integrity verification. SPGAJC is constructed with polypropylene structural components and thermal bonding sealing, supporting stable filtration and low extractables intent for sensitive liquid applications. Because the membrane is hydrophilic, the capsule is commonly used for direct filtration of water based liquids without extra wetting steps.
In many production lines, general-purpose capsule filters featuring nylon membranes are positioned as versatile products for clarification and the reduction of particulate impurities; they are particularly well-suited for applications requiring reproducible results and verification via integrity testing.
The pleated structure increases effective area, supporting higher flow and helping maintain low pressure drop during operation.
Each SPGAJC capsule is 100% integrity tested, supporting consistent performance expectations and simplifying qualification routines.
Thermal bonding supports adhesive free construction intent and helps manage extractables concerns in sensitive liquid service.
The capsule is designed to minimize fiber release and to support low extractables, helping protect product cleanliness.
Often used to reduce particulates that affect clarity and to protect downstream filling and packaging operations. Pore size selection depends on target clarity and upstream particulate load.
Suitable for clarification of water based streams where compatibility and stable flow matter. The hydrophilic membrane supports direct wetting and quick start up.
Applied as a polishing or clarification stage to reduce particulate contamination. Buyers typically size the capsule by throughput and allowable differential pressure to avoid frequent changeout.
Used to reduce particles that can cause visual defects or equipment issues. Compatibility and performance should be verified for each recipe and operating condition.
Commonly used for clarification and particle reduction in intermediate steps where low extractables and integrity verification are valued for documentation.
Bottled Water
Vinegar
Aqueous solutions
Beer, Wine and Spirits
Juice, Soft Drinks, Edible Oils
Pharmaceutical intermediates
Every wetted part and construction material of the filters strictly follows regulatory food safety criteria. The raw materials for filter media and auxiliary hardware satisfy the food contact provisions specified in FDA 21 CFR and EU Regulation 10/2011, eliminating safety risks for food fluid processing scenarios.
Filter Membrane: Nylon66
Media Support: Polypropylene
End Caps: Polypropylene
Inner Core: Polypropylene
Outer Cage: Polypropylene
Sealing Method: Thermal Bonding
Filtered Hot Water 90°C (194°F), 30 minutes, multiple cycles, max 3 psid forward flow.
Autoclave 121°C (250°F), 30 min, multiple cycles.
100% integrity tested
FDA food contact compliant
Thermal bonding
Non fiber releasing
To ensure superior biocompatibility for industrial use, all plastic-based filter components fully satisfy the USP Class VI biological safety standards defined for 121°C testing scenarios.
|
Port Size |
Minimum Bubble point |
|
0.1μm |
50.8psig (3.5bar) |
|
0.2μm |
40.6psig (2.8bar) |
|
0.45μm |
26.1psig (1.8bar) |
|
1.0μm |
8.7psig (0.6bar) |
Typical Flow Rate, 1" TC, 2.5"
MS can provide integrity testing documentation (program basis), material summaries, and compliance statements aligned with USP Class VI (121°C), FDA 21 CFR, and EU 10/2011 based on stated construction materials.
For SPGAJC projects, MS supports connection options, OEM private label supply, stable batch scheduling, and technical guidance for pore size selection and capsule sizing.
To order General Application Capsule filters Nylon membrane, please select pore size and connection.
|
N |
Pore size |
Area |
Inlet |
Outlet |
|
Nylon |
001=0.1µm 002=0.2µm 004=0.45µm 006=0.65µm 010=1.0µm |
H=500cm² S=1000cm² L=2100cm² |
4N=1/4"NPT-Male 6N=3/8"NPT-Male 8N=1/2"NPT-Male 8G=1/2"BSP-Male 4NF=1/4"NPT-F 6NF=3/8"NPT-F 4C=1/4"Swagelok 5C=5/16"Swagelok 6C=3/8"Swagelok 8C=1/4"Swagelok 4Q=1/4"CPC PLC-Male 4QF=1/4"CPC PLC-Swagelok M4H=1/4"multiple Hose Barb M6H=3/8"multiple Hose Barb 6H=3/8"Hose Barb 8H=1/2"Hose Barb SH=1/4"-3/8" stepped Hose Barb 1T=1" TC MT=0.5"TC FL=female luerlok KSH=1/4"-1/2" multistepped hosebarb |
4N=1/4"NPT-Male 6N=3/8"NPT-Male 8N=1/2"NPT-Male 8G=1/2"BSP-Male 4NF=1/4"NPT-F 6NF=3/8"NPT-F 4C=1/4"Swagelok 5C=5/16"Swagelok 6C=3/8"Swagelok 8C=1/4"Swagelok 4Q=1/4"CPC PLC-Male 4QF=1/4"CPC PLC-Swagelok M4H=1/4"multiple Hose Barb M6H=3/8"multiple Hose Barb 6H=3/8"Hose Barb 8H=1/2"Hose Barb SH=1/4"-3/8" stepped Hose Barb 1T=1" TC MT=0.5"TC FL=female luerlok KSH=1/4"-1/2" multistepped hosebarb |
Kleanpro Mini Double layer NYLON Membrane Capsule Filter
Kleanpro Mini Nylon Membrane Capsule Filter
kleanassure Bioburden Reduction Capsule Filter Nylon Membrane
General Application Capsule Filters Nylon66 Membrane
Bioburden Reduction Capsule Filter Double Layer Nylon Membrane
Bioburden Reduction Capsule Filter Nylon Membrane