5) General Application Capsule filters Nylon membrane
Summary
Get a quote for General Application Capsule filters Nylon membrane from MS. The SPGAJC pleated cartridge capsule uses a single layer hydrophilic nylon 66 membrane, offers high flow at low pressure drop, and is designed for low extractables. Each unit is 100% integrity tested and built with thermal bonding sealing for clean construction intent.
Introduction
Buy General Application Capsule filters Nylon membrane from MS when your process requires a hydrophilic nylon 66 capsule that balances throughput, cleanliness, and documented integrity verification. SPGAJC is constructed with polypropylene structural components and thermal bonding sealing, supporting stable filtration and low extractables intent for sensitive liquid applications. Because the membrane is hydrophilic, the capsule is commonly used for direct filtration of water based liquids without extra wetting steps.
In many production lines, general-purpose capsule filters featuring nylon membranes are positioned as versatile products for clarification and the reduction of particulate impurities; they are particularly well-suited for applications requiring reproducible results and verification via integrity testing.
Features and Functional Advantages
Pleated nylon 66 membrane for efficient filtration
The pleated structure increases effective area, supporting higher flow and helping maintain low pressure drop during operation.
100% integrity tested for out of box consistency
Each SPGAJC capsule is 100% integrity tested, supporting consistent performance expectations and simplifying qualification routines.
Thermal bonding sealing method
Thermal bonding supports adhesive free construction intent and helps manage extractables concerns in sensitive liquid service.
Non fiber releasing design intent and low extractables
The capsule is designed to minimize fiber release and to support low extractables, helping protect product cleanliness.
Application Scenarios and Buyer Intent
Bottled water
Often used to reduce particulates that affect clarity and to protect downstream filling and packaging operations. Pore size selection depends on target clarity and upstream particulate load.
Vinegar and aqueous solutions
Suitable for clarification of water based streams where compatibility and stable flow matter. The hydrophilic membrane supports direct wetting and quick start up.
Beer, wine and spirits
Applied as a polishing or clarification stage to reduce particulate contamination. Buyers typically size the capsule by throughput and allowable differential pressure to avoid frequent changeout.
Juice, soft drinks, edible oils
Used to reduce particles that can cause visual defects or equipment issues. Compatibility and performance should be verified for each recipe and operating condition.
Pharmaceutical intermediates
Commonly used for clarification and particle reduction in intermediate steps where low extractables and integrity verification are valued for documentation.
Typical Application
Bottled Water
Vinegar
Aqueous solutions
Beer, Wine and Spirits
Juice, Soft Drinks, Edible Oils
Pharmaceutical intermediates
Food Safety Compliance
Every wetted part and construction material of the filters strictly follows regulatory food safety criteria. The raw materials for filter media and auxiliary hardware satisfy the food contact provisions specified in FDA 21 CFR and EU Regulation 10/2011, eliminating safety risks for food fluid processing scenarios.
Construction Materials
Filter Membrane: Nylon66
Media Support: Polypropylene
End Caps: Polypropylene
Inner Core: Polypropylene
Outer Cage: Polypropylene
Sealing Method: Thermal Bonding
Sanitization and Sterilization
Filtered Hot Water 90°C (194°F), 30 minutes, multiple cycles, max 3 psid forward flow.
Autoclave 121°C (250°F), 30 min, multiple cycles.
Benefits
100% integrity tested
FDA food contact compliant
Thermal bonding
Non fiber releasing
Toxity
To ensure superior biocompatibility for industrial use, all plastic-based filter components fully satisfy the USP Class VI biological safety standards defined for 121°C testing scenarios.
Integrity (Water wetted membrane)
|
Port Size |
Minimum Bubble point |
|
0.1μm |
50.8psig (3.5bar) |
|
0.2μm |
40.6psig (2.8bar) |
|
0.45μm |
26.1psig (1.8bar) |
|
1.0μm |
8.7psig (0.6bar) |
Typical Flow Rate
Typical Flow Rate, 1" TC, 2.5"
Quality and Compliance
MS can provide integrity testing documentation (program basis), material summaries, and compliance statements aligned with USP Class VI (121°C), FDA 21 CFR, and EU 10/2011 based on stated construction materials.
Service for Liquid Filtration Buyers
For SPGAJC projects, MS supports connection options, OEM private label supply, stable batch scheduling, and technical guidance for pore size selection and capsule sizing.
Ordering Information
To order General Application Capsule filters Nylon membrane, please select pore size and connection.

Kleanpro Mini Double layer NYLON Membrane Capsule Filter
Kleanpro Mini Nylon Membrane Capsule Filter
kleanassure Bioburden Reduction Capsule Filter Nylon Membrane
General Application Capsule Filters Nylon66 Membrane
Bioburden Reduction Capsule Filter Double Layer Nylon Membrane
Bioburden Reduction Capsule Filter Nylon Membrane