Home > Products > Nylon Capsule Filter > General Application Capsule Filters Nylon Membrane
General Application Capsule Filters Nylon Membrane
  • General Application Capsule Filters Nylon MembraneGeneral Application Capsule Filters Nylon Membrane

General Application Capsule Filters Nylon Membrane

5) General Application Capsule filters Nylon membraneSummaryGet a quote for General Application Capsule filters Nylon membrane from MS. The SPGAJC pleated cartridge capsule uses a single layer hydrophilic nylon 66 membrane, offers high flow at low pressure drop, and is designed for low extractables.......

Send Inquiry

Product Description

5) General Application Capsule filters Nylon membrane


Summary

Get a quote for General Application Capsule filters Nylon membrane from MS. The SPGAJC pleated cartridge capsule uses a single layer hydrophilic nylon 66 membrane, offers high flow at low pressure drop, and is designed for low extractables. Each unit is 100% integrity tested and built with thermal bonding sealing for clean construction intent.


Introduction

Buy General Application Capsule filters Nylon membrane from MS when your process requires a hydrophilic nylon 66 capsule that balances throughput, cleanliness, and documented integrity verification. SPGAJC is constructed with polypropylene structural components and thermal bonding sealing, supporting stable filtration and low extractables intent for sensitive liquid applications. Because the membrane is hydrophilic, the capsule is commonly used for direct filtration of water based liquids without extra wetting steps.


In many production lines, general-purpose capsule filters featuring nylon membranes are positioned as versatile products for clarification and the reduction of particulate impurities; they are particularly well-suited for applications requiring reproducible results and verification via integrity testing.





Features and Functional Advantages


Pleated nylon 66 membrane for efficient filtration

The pleated structure increases effective area, supporting higher flow and helping maintain low pressure drop during operation.


100% integrity tested for out of box consistency

Each SPGAJC capsule is 100% integrity tested, supporting consistent performance expectations and simplifying qualification routines.


Thermal bonding sealing method

Thermal bonding supports adhesive free construction intent and helps manage extractables concerns in sensitive liquid service.


Non fiber releasing design intent and low extractables

The capsule is designed to minimize fiber release and to support low extractables, helping protect product cleanliness.





Application Scenarios and Buyer Intent

Bottled water

Often used to reduce particulates that affect clarity and to protect downstream filling and packaging operations. Pore size selection depends on target clarity and upstream particulate load.


Vinegar and aqueous solutions

Suitable for clarification of water based streams where compatibility and stable flow matter. The hydrophilic membrane supports direct wetting and quick start up.


Beer, wine and spirits

Applied as a polishing or clarification stage to reduce particulate contamination. Buyers typically size the capsule by throughput and allowable differential pressure to avoid frequent changeout.


Juice, soft drinks, edible oils

Used to reduce particles that can cause visual defects or equipment issues. Compatibility and performance should be verified for each recipe and operating condition.


Pharmaceutical intermediates

Commonly used for clarification and particle reduction in intermediate steps where low extractables and integrity verification are valued for documentation.






Typical Application

Bottled Water

Vinegar

Aqueous solutions

Beer, Wine and Spirits

Juice, Soft Drinks, Edible Oils

Pharmaceutical intermediates


Food Safety Compliance

Every wetted part and construction material of the filters strictly follows regulatory food safety criteria. The raw materials for filter media and auxiliary hardware satisfy the food contact provisions specified in FDA 21 CFR and EU Regulation 10/2011, eliminating safety risks for food fluid processing scenarios.


Construction Materials

Filter Membrane: Nylon66

Media Support: Polypropylene

End Caps: Polypropylene

Inner Core: Polypropylene

Outer Cage: Polypropylene

Sealing Method: Thermal Bonding


Sanitization and Sterilization

Filtered Hot Water 90°C (194°F), 30 minutes, multiple cycles, max 3 psid forward flow.

Autoclave 121°C (250°F), 30 min, multiple cycles.


Benefits

100% integrity tested

FDA food contact compliant

Thermal bonding

Non fiber releasing


Toxity

To ensure superior biocompatibility for industrial use, all plastic-based filter components fully satisfy the USP Class VI biological safety standards defined for 121°C testing scenarios.


Integrity (Water wetted membrane)

Port Size

Minimum Bubble point

0.1μm

50.8psig (3.5bar)

0.2μm

40.6psig (2.8bar)

0.45μm

26.1psig (1.8bar)

1.0μm

8.7psig (0.6bar)



Typical Flow Rate

Typical Flow Rate, 1" TC, 2.5"



Quality and Compliance

MS can provide integrity testing documentation (program basis), material summaries, and compliance statements aligned with USP Class VI (121°C), FDA 21 CFR, and EU 10/2011 based on stated construction materials.


Service for Liquid Filtration Buyers

For SPGAJC projects, MS supports connection options, OEM private label supply, stable batch scheduling, and technical guidance for pore size selection and capsule sizing.


Ordering Information

To order General Application Capsule filters Nylon membrane, please select pore size and connection.


Hot Tags:
Related Category
Send Inquiry
Please Feel free to give your inquiry in the form below. We will reply you in 24 hours.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy